An earth fault is where an unwanted electrical contact is established between a current-carrying conductor and an earthed object, for example, the metal structure of the system or the earth. Earth faults are usually the result of installation mistakes, weather, wear and tear on components, rodent and pest infestation, or damage to the installation. Faults also occur due to improper wiring, improper cable fixing, or installation damage. Severe weather conditions such as temperature changes and UV radiation can cause insulation to degrade over the long term. Defective connectors, defective junction boxes, and aged PV modules can enhance the risk of faults. Rodents gnawing on insulation can provide unintentional grounding paths. With all these reasons, how can the owners of PV systems themselves reduce their risks?
Identifying Earth Faults
The earliest detection of earth faults is needed to reduce the amount of damage and ensure optimal efficiency of the system. Simple inspection of the system can disclose glaring evidence of faults like scorch marks or charring on PV modules or connectors, melted or browned insulations, loose or unbundled wires. While simple tests will from time to time detect earth faults, not every fault is perceptible, therefore other methods have to be utilized.
Electric testing is commonly done to find the location of an earth fault. Voltage-to-ground testing will expose an unwanted contact, and insulation resistance measurement with a megohmmeter will test insulation resistance between conductors and earthed parts. A lower abnormal reading of resistance may indicate insulation breakdown. Ground fault detection is included in new PV inverters and monitoring gear. These equipment constantly check for leakage currents and can alert operators to an earth fault, making it easier to detect. But naturally, if there are several detection schemes, what is best suited for various situations?
Safety Precautions When Dealing with Earth Faults
Dealing with electrical faults in PV systems is dangerous. Safety procedures must be observed at all times to avoid injury and equipment damage. When inspecting and repairing PV systems, the technicians must employ personal protective equipment in the form of insulated gloves, fire-resistant apparel, safety glasses, and arc flash face shields for high-voltage systems. Prior to conducting maintenance work, the system should be de-energized by disconnecting the PV array and applying lockout/tagout procedures so that no individual will inadvertently re-energize it during repairs. It is more secure to avoid working on PV systems during harsh weather conditions like rain or heavy winds, which cause an electric shock. What are the essential procedures to follow before handling a suspected earth fault to guarantee technician safety?
Repair Strategies for Earth Faults
After detection of an earth fault, system integrity restoration is essential immediately. If the fault occurs in a local module, conductor, or connector, replacement of the faulty element is the most frequent remedy. This involves the replacement of bad PV modules for faults that occur due to faulty internal cell, new insulation and wiring to replace damaged wiring or insulation, and secure connection of loose connectors as well as checking for proper grounding. For minor insulation faults, liquid insulation, electrical tape, or heat shrink tubing can be utilized by the technicians to regain protective coverings. But in extensive damage, it is advisable to replace the entire conductor.
In case of a fault in the PV module or inverter, it is advisable to contact the manufacturer for warranty replacements or technical assistance. Instructions on how to handle faults are normally provided by most manufacturers and can also provide replacements in the event of defects. Regular system maintenance is required for prevention of future earth fault occurrences. Conducting routine insulation resistance tests, checking connectors and cables for damage, and having all components of the system fastened securely and properly earthed can be ensured to prevent problems. How often, however, should one perform these tests in order to guarantee prolonged reliability?
Meeting Australian Standards
In Australia, PV systems must adhere to applicable electrical safety standards, such as AS/NZS 5033 for PV array installation and safety and AS/NZS 3000 (Wiring Rules) for general electrical installation safety and Clean Energy Council (CEC) Guidelines for best practice for safe and efficient PV system installations. Adherence to these standards makes PV systems safe, reliable, and in compliance with the law.