How Utilisation Categories Affect Equipment Selection

From an engineering standpoint, utilisation categories identify the kind of electrical loading and switching operation the device can accommodate. As opposed to presuming that all loads are alike, utilisation categories understand that:

  • • Motor-driven loads produce high starting currents
  • • Loads with resistance do not change easily
  • • Loads with inductance cause arcing during switching
  • • Some loads switch often while energised

Thus, rather than asking, “How much current is this device capable of handling?”, the better question would be:

“What are the electrical stresses this device is subjected to when in use?”

This is precisely what utilisation categories tell us.

Why contactor selection depends heavily on utilisation categories

The contactor provides another straightforward example of utilisation classification impacting sizing and design.

It is often thought that a contactor is specified with some predetermined current rating. Actually, the rating of the contactor is completely dependent on the duty cycle classification.

To provide some numbers:

  • – A certain contactor could have a 25-A rating when classifying it according to the AC-1 duty cycle
  • – At the same time, the same contactor would have a considerably lower current capacity, say, 9-12A when applied in the AC-3 duty cycle

That happens due to a substantial increase in switching wear caused by high inrush currents and arc formation while operating.

Specifically:

  • – AC-1 is applicable in the cases of heaters, lamps, resistive non-inductive loads
  • – AC-3 is used for squirrel-cage induction motors with high start-up current but infrequent switching operation
  • – AC-4 is recommended for severe motor cycles such as inching, plugging, or frequent reverse operations

The incorrect choice of contactors leads to excessive wear in contacts and may result in unexpected device failure.

In Australia, motor duty is the most common type of load, thus contactors should be chosen with caution at HVAC, conveyors, pump stations, and other industrial plants.

How utilisation categories influence circuit breaker selection

Circuit breakers are affected by utilisation, too, although in a somewhat different sense. Circuit breakers are not classified into AC-1, AC-3 categories; rather, they can be categorized into either category A or B according to IEC 60947-2.

Category A breakers

They have been created to:

  • • Work without any deliberate time lag
  • • Act instantly upon the occurrence of a fault
  • • Offer minimum protection

They are often applied in simple radial networks where selectivity is not essential.

Category B breakers

They are meant for higher coordination:

  • • They endure short-circuit currents for a certain time
  • • They permit lower-rated devices to act first on the fault
  • • They help ensure selectivity in complicated systems

In engineering practice, category B circuit breakers are employed whenever continuous operation is significant. Take the case of a factory or hospital where you need to isolate just the part with the problem, but not the whole panel.

The main point to remember here is that breaker specification is more than just capacity for interruption. It involves system response to the event as well as whether upstream equipment is supposed to trip or remain connected.

Switch and isolator selection: where utilisation categories are often overlooked

Categories are used in switches and switch disconnectors and can be categorized as follows:

  • • AC-21 for resistive loads
  • • AC-22 for both resistive and inductive loads
  • • AC-23 for high inductive motor loads

This area often causes mistakes among many other field installations.

For instance, using an AC-21 isolator in a motor circuit seems acceptable since the current rating is similar. Nevertheless, during the switching process, the high inductance causes arcing at the contacts leading to:

  • • Contact welding and pitting
  • • Higher heat dissipation
  • • Earlier isolator malfunctioning

Conversely, AC-23 switch caters for the arcing problems associated with motor loads including higher current rating and inrush currents.

For switchboards within Australia, especially ones that are based on AS/NZS installations, choosing the appropriate switch is vital.

Practical engineering approach to selection

Utilization categories should not be something that you will “check at the end.” Utilization categories must be considered when selecting devices.

Here’s how a proper procedure goes:

Start with determining the nature of the load. Resistive, inductive, or motor loads? Most of the time, this already determines the utilization category.

Follow with analysis of operational conditions. These include starting current, number of switching cycles, frequent reversing, and duty cycles. There is a huge difference between a motor that starts only once in a while and a hoist on a crane which reverses a lot of times.

Choose the right utilization category to make sure the equipment is tested accordingly.

Coordinate. Make sure that your circuit breakers are still selective and properly fault-coordinated. With contactors and switches, make sure the rating for both mechanical and electrical endurance matches the application.

Why this matters in Australian installations

In Australia, electrical installations can often be subjected to difficult working conditions such as high ambient temperatures, extended cable lengths, and high motor loads. Such a situation makes the right choice of components all the more essential.

The results are inevitable when categories are neglected:

  • • Contactors malfunction in motor circuits
  • • Switches get overheated with inductive load operations
  • • Circuit breakers lack coordination and cause complete system tripping
  • • Downtime becomes frequent and increases maintenance costs

However, if categories are properly considered during the choice of components, the system will function optimally for its rated capacity.

We design and manufacture high-quality switchboards. Contact us today to discuss your requirements and get started!

Tags: protection relays
Electrical Switchboard Manufacturer
  • BESS & Batteries
  • Electric Vehicles & EV Charging Switchboards
  • Electrical Enclosures
  • Engineering Resources
  • High & Medium Voltage
  • Integrating Diesel & Backup Generation
  • Power Quality Analysis
  • Protection Relays & Injection Testing
  • Renewable Energy & Power Generation
  • Solar Standards: AS/NZS 4777 2024
  • Switchboards & Components
  • Virtual Power Plants & Smart Grids
  • Wiring Rules AS/NZS 3000
  • electrical switchboard | electrical switchboards
    What is Edge Computing? How it helps power distribution?
    Edge computing refers to an arrangement where data processing occurs… Read more: What is Edge Computing? How it helps power distribution?
  • electrical switchboard | electrical switchboards
    What is Net Zero Building? How it uses Smart Switchboards?
    Net Zero building is designed in a way that allows… Read more: What is Net Zero Building? How it uses Smart Switchboards?
  • electrical switchboard | electrical switchboards
    What is Paralleling Switchgear? How it works?
    Paralleling switchgear is basically a low-voltage switchboard used to control… Read more: What is Paralleling Switchgear? How it works?
  • electrical switchboard | electrical switchboards
    What is Electrification? Understanding the Basics
    Electrification is turning into one of the major trends in… Read more: What is Electrification? Understanding the Basics
  • What is a Data Center?
    What Is a Data Center? Discover How it works!
    DATA CENTER – Each day, we use the internet and… Read more: What Is a Data Center? Discover How it works!
  • 250A Chassis
    Understanding a 250A Chassis in a Distribution Board
    A 250A chassis is an example of a type of… Read more: Understanding a 250A Chassis in a Distribution Board
  • arc flash protection
    Arc Flash Protection – What Really Happens When Systems Fail
    The technician didn’t hear anything unusual. No alarm. No warning.… Read more: Arc Flash Protection – What Really Happens When Systems Fail
  • Do All Switchboards Require a Dedicated Room?
    Do All Switchboards Require a Dedicated Room?
    Switchboards are usually mounted on a garage wall, sometimes in… Read more: Do All Switchboards Require a Dedicated Room?
  • Is SMA leaving the Australian market?
    Why is SMA shutting down in Australia? Explained!
    Is SMA really going to close down? SMA’s move in… Read more: Why is SMA shutting down in Australia? Explained!
  • electrical switchboard | electrical switchboards
    What Are Electronic Overload Relays? Explained!
    Electronic overload relay sends a signal to the contactor to… Read more: What Are Electronic Overload Relays? Explained!
  • electrical switchboard | electrical switchboards
    AS/NZS 3000 Switchboard Rules – Complete Guide for Compliance and Safety
    Switchboard rules is critical for ensuring electrical safety and functionality.… Read more: AS/NZS 3000 Switchboard Rules – Complete Guide for Compliance and Safety
  • electrical switchboard | electrical switchboards
    AS/NZS 3000 Switchboard Clearances: Safety Rules Every Electrician Must Know
    Ensuring proper switchboard clearances is crucial for maintaining safety and… Read more: AS/NZS 3000 Switchboard Clearances: Safety Rules Every Electrician Must Know

Contact Us

Phone: 02 9558 2480

Email: contact@cleantechcontrols.com.au

Sales (VIC) 0435 812 094

Sales (NSW) 0405 352 840

Sales (WA) 0419 423 609

Useful Links

  • Home
  • Electrical Switchboards
  • Injection Testing & PQA
  • Engineering Services
  • Technical Articles
  • About Us
  • Contact Us
© 2020 Clean Technology Controls. All Rights Reserved.