Types of Distribution Systems under AS/NZS 3000

A distribution system is essentially a network that delivers electrical power throughout a building. It takes electricity supplied by the utility and directs it to where it is needed, whether that’s powering your living room lights, a commercial office’s air conditioning, or a large motor in a factory. Distribution systems are found in every type of building—residential, commercial, and industrial—but the complexity, capacity, and design vary depending on the type of building and its electrical requirements.

Residential Distribution Systems

Most Australians are aware of the electrical distribution system in a typical domestic dwelling. The electricity bought from the energy supplier enters the dwelling via a metering system, which measures the consumption of electricity. From the meter, the electricity is distributed to the main switchboard or load center, which is the hub of the electrical distribution system in the dwelling. At this point, the electricity is split into branch circuits that distribute electricity to the lighting, power points, and appliances.

The domestic electrical distribution system is quite simple, but it still has to adhere to the wiring standards AS/NZS 3000. The branch circuits are sized correctly for the load they are carrying, circuit protective devices such as circuit breakers are provided, and the earthing system is designed to provide safety in the event of a fault. Even in a simple domestic dwelling, electrical safety, circuit separation, and load balancing are critical.

For instance, a standard domestic dwelling in Australia could have a 230V single-phase supply with a main switch of 100A capacity. Branch circuits are used to distribute power to lighting, power points, and high-load appliances such as electric ovens or air conditioners. Main switchboards usually have spare ways for extra circuits in case of future expansion, which is an important factor in AS/NZS 3000.

Commercial and Industrial Distribution Systems

Commercial and industrial distribution networks are more intricate compared to residential ones. In contrast to residential networks, commercial and industrial ones have to deal with heavier electrical loads, sometimes measured in hundreds of kilowatts. They consist of a variety of equipment, such as air conditioners, lighting, large motors, and industrial machines.

A commercial or industrial distribution network will consist of metering equipment for measuring the consumption of electricity, main and branch disconnects for disconnecting sections of the network safely, protective devices for preventing overload and faults, switching devices for starting or stopping the flow of power, conductors and transformers sized according to the expected load, and switchgear or switchboards for efficient distribution.

However, appropriate design is a must. A properly designed distribution network will ensure safe and efficient distribution of electricity, besides meeting the requirements of future extensions. In an industrial setup, where down time can prove to be very costly, reliability is as important as capacity.

For instance, in a manufacturing unit, there may be a three-phase, 415V supply to a main switchboard. The power is subsequently distributed to the branch switchboards, which in turn supply motors, lighting, air-conditioning units, and other machinery. The protective devices are designed based on the load as well as the type of machinery being supplied, and are designed to meet the requirements of AS/NZS 3000.

Types of Distribution Systems by Topology

Distribution networks can also be categorized based on their topologies, which are the patterns of electrical power paths. A radial network is the simplest type, where the power travels in one direction from the substation to the load. Although it is easy and cheap to set up, a fault in the line may result in no power supply to the loads on the other side of the line. This type of network is normally used in rural and sparsely populated suburbs.

Ring main distribution networks are normally used in urban areas. In this type, the feeders are in a closed loop, meaning that the loads can be supplied from different sides. If a part of the network is switched off for maintenance, the other parts will still get their power supplies. This is why it is normally used in Australian residential and commercial networks.

For large cities and industrial areas, mesh or interconnected networks are established. Several substations and feeders are interconnected, forming a network that is highly redundant and reliable. Spot networks provide a common bus from several transformers and are applied in critical facilities like hospitals, data centers, and high-rise office buildings, where the availability level has to be close to 100%.

In rural areas, single-wire earth return (SWER) systems can be applied. In these systems, a single high-voltage wire uses the earth as the return path, making it a relatively cheap method of distribution over long distances. Mini-grids are smaller standalone distribution networks that can supply isolated communities or power renewable energy-based installations, which may include solar, batteries, or micro-generators.

Distribution Systems by Voltage Level

The voltage levels in the distribution network are generally divided into two categories: primary and secondary. The high voltage, ranging from 11kV to 33kV, is known as primary distribution and is used to supply the local area from substations. This enables the electricity to be transmitted over long distances with less loss. The secondary distribution transforms the voltage to suitable levels for the end-use apparatus, like 230V single-phase or 400V three-phase, through the use of distribution transformers.

In Australian residential areas, the low voltage three-phase supply is normally used. The commercial and industrial areas, on the other hand, use the high voltage three-phase supply depending on the load. Careful planning ensures that the primary and secondary distribution networks are safe, efficient, and AS/NZS 3000 compliant.

Residential, Commercial, and Industrial Comparison

The distribution systems differ considerably between residential, commercial, and industrial establishments. The residential distribution system is quite straightforward, with the supply of low voltage single-phase power to lighting and small appliances. The commercial distribution system has to deal with a combination of 230V and 400V loads, with multiple switchboards and branch panels. The industrial distribution system deals with high-power motors, heavy machinery, and complex automation systems, with main and branch switchboards, transformers, and advanced protective devices.

The AS/NZS 3000 standard ensures that all these distribution systems meet rigorous safety requirements. Sound earthing practices, circuit protection, and loading are critical to avoid dangers and provide for future expansions. Irrespective of the type of establishment, careful planning and adherence to Australian wiring standards are the solution to a safe and sound electrical distribution system.

We design and manufacture high-quality switchboards. Contact us today to discuss your requirements and get started!

Tags: switchboards
Electrical Switchboard Manufacturer
  • BESS & Batteries
  • Electric Vehicles & EV Charging Switchboards
  • Electrical Enclosures
  • Engineering Resources
  • High & Medium Voltage
  • Integrating Diesel & Backup Generation
  • Power Quality Analysis
  • Protection Relays & Injection Testing
  • Renewable Energy & Power Generation
  • Solar Standards: AS/NZS 4777 2024
  • Switchboards & Components
  • Virtual Power Plants & Smart Grids
  • Wiring Rules AS/NZS 3000
  • electrical switchboard | electrical switchboards
    What is Edge Computing? How it helps power distribution?
    Edge computing refers to an arrangement where data processing occurs… Read more: What is Edge Computing? How it helps power distribution?
  • electrical switchboard | electrical switchboards
    What is Net Zero Building? How it uses Smart Switchboards?
    Net Zero building is designed in a way that allows… Read more: What is Net Zero Building? How it uses Smart Switchboards?
  • electrical switchboard | electrical switchboards
    What is Paralleling Switchgear? How it works?
    Paralleling switchgear is basically a low-voltage switchboard used to control… Read more: What is Paralleling Switchgear? How it works?
  • electrical switchboard | electrical switchboards
    What is Electrification? Understanding the Basics
    Electrification is turning into one of the major trends in… Read more: What is Electrification? Understanding the Basics
  • What is a Data Center?
    What Is a Data Center? Discover How it works!
    DATA CENTER – Each day, we use the internet and… Read more: What Is a Data Center? Discover How it works!
  • 250A Chassis
    Understanding a 250A Chassis in a Distribution Board
    A 250A chassis is an example of a type of… Read more: Understanding a 250A Chassis in a Distribution Board
  • arc flash protection
    Arc Flash Protection – What Really Happens When Systems Fail
    The technician didn’t hear anything unusual. No alarm. No warning.… Read more: Arc Flash Protection – What Really Happens When Systems Fail
  • Do All Switchboards Require a Dedicated Room?
    Do All Switchboards Require a Dedicated Room?
    Switchboards are usually mounted on a garage wall, sometimes in… Read more: Do All Switchboards Require a Dedicated Room?
  • Is SMA leaving the Australian market?
    Why is SMA shutting down in Australia? Explained!
    Is SMA really going to close down? SMA’s move in… Read more: Why is SMA shutting down in Australia? Explained!
  • electrical switchboard | electrical switchboards
    What Are Electronic Overload Relays? Explained!
    Electronic overload relay sends a signal to the contactor to… Read more: What Are Electronic Overload Relays? Explained!
  • electrical switchboard | electrical switchboards
    AS/NZS 3000 Switchboard Rules – Complete Guide for Compliance and Safety
    Switchboard rules is critical for ensuring electrical safety and functionality.… Read more: AS/NZS 3000 Switchboard Rules – Complete Guide for Compliance and Safety
  • electrical switchboard | electrical switchboards
    AS/NZS 3000 Switchboard Clearances: Safety Rules Every Electrician Must Know
    Ensuring proper switchboard clearances is crucial for maintaining safety and… Read more: AS/NZS 3000 Switchboard Clearances: Safety Rules Every Electrician Must Know

Contact Us

Phone: 02 9558 2480

Email: contact@cleantechcontrols.com.au

Sales (VIC) 0435 812 094

Sales (NSW) 0405 352 840

Sales (WA) 0419 423 609

Useful Links

  • Home
  • Electrical Switchboards
  • Injection Testing & PQA
  • Engineering Services
  • Technical Articles
  • About Us
  • Contact Us
© 2020 Clean Technology Controls. All Rights Reserved.